TRH System Start-Up
  • Install Airtronic Burner in Tray Ration Heater

  • Fill Tray Ration Heater with water so low water sensor is completely covered

  • If the fuel can has a leak proof cap installed, remove it and replace it with the fuel line adapter kit. Check to be sure the plastic dip tube securely attached to the adapter cap. 
    (Figure 4-1)
  • NOTE: always ensure low water sensor is covered to preclude heat damage to system by running when dry.  

  • Vent fuel can by loosening vent cock on top of the adapter kit (turn completely counter-clockwise to full open position).
    (Figure 4-2)

  • Ensure fuel filter is not clogged and fuel lines are connected properly and not kinked.  

  • Connect power cord to top of Airtronic Burner control box base

  • Plug in power cord from the Tray Ration Heater electrical control box to a 120 VAC, 60 HZ outlet.

 

  • Pull red, pull-on/push-off switch on Tray Ration Heater to ON position. 
  • Ensure circuit breaker is depressed.

  • Prime the Airtronic Burner during pre-purge by depressing the starting button inlet valve for 10 seconds.  Simultaneously close off the finger priming port with a finger to further enhance the priming process. (Figure 4-4) If Airtronic Burner does not start, the Airtronic Burner will go into “lockout” and the reset button on the control box will illuminate with a red LED light.
  • Wait 60 seconds, depress reset button, and repeat prevoius step
  • In a dry system (no fuel in burner or fuel line), the above-mentioned priming process may be required up to 3 times.  If the burner does not prime and light off after 3 priming attempts, trouble-shooting steps should be taken to determine the cause.